Single-Use Pressure Sensors

Our PendoTECH Single-Use Pressure Sensor accurately measures static and dynamic pressure of gases and liquids in your biopharmaceutical processes.

  • Compatible with gamma irradiation
  • May be repeatedly cleaned and re-used
  • Unobstructed flow path
Category:

Created In A Certified Facility

Our PendoTECH Single-Use Pressure Sensors are manufactured in a FDA Registered, ISO 13485 certified facility, with a Class 100,000 cleanroom.

Accurate Static and Pressure Measurement

Our innovative PendoTECH Single-Use Pressure Sensors can help to streamline your bioprocessing, allowing for the accurate measurement of static and dynamic pressure of gases and liquids in your biopharmaceutical processes.

Overview

Features & Benefits

  • May be repeatedly cleaned and re-used
  • Available with diameters from 1/16 to 1 inch (0.16 to 2.5 cm) inner diameter
  • Operating range from -7 to 75 psi (-0.48 to 5.2 bar)
  • Unobstructed flow path & no dead legs provides dramatically reduced hold-up volume versus stainless steel transducers or gauges
  • 100% tested for accuracy and leaks during manufacturing
  • Available in polycarbonate or caustic resistant polysulfone material of construction
  • All fluid path materials meet USP Class VI requirements
  • Certificate of quality included with lot certification; individual NIST Calibration Certificates are optional
  • Compatible with gamma irradiation

Applications

  • Monitoring of bioreactors
  • Diafiltration
  • Tangential Flow Filtration (TFF)
  • Virus Filtration
  • Harvesting
  • Fill and Finish
  • Perfusion
  • Nano Filtration
  • Chromatography
  • Sterile Filtration
  • Research
  • Process Development
  • As well as many other applications

Technical Specs

Accuracy Better than +/- 2% of reading in the range of 0 to 6 psi (0 to 0.41 bar) Better than +/- 3% of reading in the range of 6 to 30 psi (0.41 to 2.07 bar)
In range of 30 to 60 psi (2.07 to 4.14 bar) typically better than +/- 5% of reading
Pressure range -7 to 75 psi (-0.48 to 5.2 bar)
Biocompatibility All materials in contact with product fluid path meet USP Class VI requirements, both pre and post gamma exposure
Manufacturing Environment FDA Registered, ISO 13485 certified facility; Class 100,000 clean room
Gamma Irradiation Up to 50 kiloGrays
Operating temperature 2° C to 50° C (other ranges with process qualification)
Storage temperature -25° C to 65° C
Input/Output impedance 270 Ohms to 400 Ohms
Excitation voltage 2.5 to 10 volts DC
Sensor Output 0.2584 mV/psi/Volt
Natural Frequency > 200 Hz in saline
Connector Custom molded water-tight 4 pin connector; signal +/- and excitation +/-
Packaging White Tyvek® and clear pouch with easy-open chevron seal; box of 25 sensors in polyethylene bags (except sterile sensors are not in polybags)